Abstract

The vibration caused by ice shedding from overhead transmission line will lead to a great damage to transmission line in ice disaster areas, so it is of great significance for line design to research the vibration characters caused by ice shedding. In order to research the characters of tensile force in ice shedding conductor, the ice shedding phenomenon is simulated in laboratory by a single conductor between isolated span. The result shows that: the ice-shedding response amplitude will increase as the increase of ice thickness, the decrease of the sag-span ratio or the increase the shedding ice quantity; the max dynamic tension caused by part of ice shedding from conductor may larger than the whole ice-shedding.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.