Abstract

A liquid bridge of a floating half zone consisting of liquid mercury sealed in a glass tube with nitrogen atmosphere was used for the experiment of thermocapillary convection with a low Prandtl number liquid. A non-contacted diagnostic method was developed to monitor the surface flow and the surface oscillation. A growing surface film (or skin) is a crucial source to suppress thermocapillary convection, and is discussed in this paper. For the case of a mercury liquid bridge, the critical Marangoni number was obtained as 900, and the oscillatory frequency was around 5 Hz.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.