Abstract

Short-term mechanical circulatory support in the pediatric population with acute cardiac failure has traditionally been limited to extracorporeal membrane oxygenation given the limited availability of pediatric-sized pumps. The Levitronix CentriMag system (Thoratec Corporation, Pleasanton, CA, USA) offers expanded options for short-term support for this population. We report our experience with the successful use of the CentriMag in the pediatric population as a bridge to decision after postcardiotomy ventricular failure and as a bridge to recovery after heart transplantation. The first patient was bridged to a long-term HeartMate II (Thoratec Corporation) as a bridge to potential recovery. The second patient was supported after severe graft failure post heart transplantation, with a full recovery. The Levitronix CentriMag has proven to be a versatile, safe, and effective short-term circulatory support system for our pediatric patients.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.