Abstract

From a viewpoint of heat leakage, there were two incidents during HTTR power-rise-tests. One was a temperature rise of the primary upper shielding, and the other was a temperature rise of the core support plate. Causes of the both incidents were small amount of helium flow in structures. For the temperature rise of the primary upper shielding, countermeasures to reduce the small amount of helium flow, enhancement of heat release and installation of thermal insulator were taken. For the temperature rise of the core support plate, temperature evaluations were carried out again considering the small amount of helium flow and design temperature of the core support plate was revised. By these countermeasures, the both temperatures were kept below their limits.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.