Abstract
Between April 1985 and April 1993, 100 consecutive men underwent lower urinary tract reconstruction after cystectomy. An ileal low pressure reservoir using the Goodwin cup-patch principle was combined with an afferent ileal tubular segment. The early complication rate was 11 percent, including 2 postoperative deaths due to septicemia. After a median followup of 27 months (range 3 to 96) 14 patients required surgery for late complications (intestinal obstruction, urethral stricture or tumor recurrence, hernia or ureteral stenosis). A total of 32 patients died of metastatic bladder cancer and 7 died of other causes. The functional capacity of the bladder substitute was increased to the desired 450 to 500 ml. after 3 to 12 months, which was paralleled by improving urinary continence. After 1 year 92 percent of the patients were continent by day and after 2 years 80 percent were continent at night. Upper tract surveillance with excretory urography, renal ultrasound and serum creatinine estimation has shown 4 left ureteral strictures but no significant upper tract deterioration or ureteral recurrence. Significant reflux was not observed during video urodynamics unless the reservoir was overfilled. During voiding, by outlet relaxation and straining if necessary, the intra-abdominal pressure increase with straining acted equally on the reservoir and ureters. Therefore, unlike voiding with a normal bladder, no isolated intravesical pressure increase occurred and, thus, there was no reflux from the reservoir. The combination of an ileal low pressure reservoir with an afferent isoperistaltic ileal segment and an open end-to-side ureteroileal anastomosis allows for radical cancer surgery with resection of the ureters where they cross the iliac vessels and minimizes the risk of ureteral stenosis. The unidirectional peristalsis of the ureters and the afferent tubular ileal segment seem to protect the upper urinary tract sufficiently. The surgical technique is straightforward and allows for later conversion to an ileal conduit if necessary. The functional results of the bladder substitute are comparable to other similar reservoir techniques, provided that the patients are carefully selected, well rehabilitated and meticulously followed.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.