Abstract

An analytical study was made in this paper to calculate the ozone generation inside an ac corona discharge reactor. The corona discharges were formed in a coaxial wire-cylinder reactor. The reactor was fed by dry air flowing with constant rates at atmospheric pressure and room temperature and stressed by an ac voltage. Concentration of the ozone generated inside the reactor was measured as a function of the ac corona current under different discharge conditions. An empirical equation was derived from the experimental results for calculating the ozone concentration generated inside the reactor. The results, that have been calculated by using the derived equation, have agreed with the experimental results over the whole range of the investigated parameters. Therefore, the derived equation represents a suitable criterion for expecting the ozone concentration that will generate by ac coronas in dry air fed coaxial wire-cylinder reactors under any discharge conditions in range of the investigated parameters.