Abstract
We assessed commonly reported patient- and circuit-related adverse events involving extracorporeal membrane oxygenation (ECMO) devices by analyzing post-marketing surveillance data from the Food and Drug Administration (FDA) Manufacturer and User Facility Device Experience (MAUDE) database. ECMO is a rescue therapy for critically ill patients requiring oxygenation and cardiopulmonary support. Key configurations include veno-venous (VV) ECMO for respiratory support and veno-arterial (VA) ECMO for cardio-respiratory support. Robust data on the most commonly reported complications associated with ECMO therapy are limited.The MAUDE database was queried from January 1, 2009, through March 31, 2019, yielding 93 reports. After excluding duplicate reports, 82 reports were included in the final analysis.Percentages represent the proportion of total submitted MAUDE reports on ECMO. Of the reported cases, 24 were VV-ECMO, 8 were VA-ECMO, and the remainder were unspecified. The most commonly reported patient-related adverse events included hemodynamic decompensation of patients (12.2%), death (12.2%), atrial perforation (7.3%), and bleeding (7.3%). The most commonly reported failure modes were in the following circuit components: mechanical pump (19.5%, mostly due to technical failure or clots), membrane oxygenator (19.5%, mostly due to tear in the membrane or temperature probe), and access cannulae (18.3%, mostly due to structural damage).Analysis of the MAUDE database demonstrates that in real-world practice, ECMO devices are associated with important complications. With broadened global utilization of ECMO devices, standard complication and failure reporting policies may improve patient selection, operator proficiency, and existing device technology.An analysis of the Food and Drug Administration's Manufacturer and User Facility Device Experience database demonstrates that in real-world practice, extracorporeal membrane oxygenation devices are associated with serious complications. The most commonly reported patient-related adverse events were hemodynamic decompensation of patients and death, and the most commonly reported failure modes were in the device's mechanical pump and membrane oxygenator.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: Cardiovascular revascularization medicine : including molecular interventions
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.