Abstract

AbstractWhen lightning connects to the ground, there is a large surge of current, called the return stroke, which is occasionally followed by a longer‐lasting steady current, called continuing current (CC). In a previous study of negative cloud‐to‐ground (−CG) flashes, we observed the growth rate of in‐cloud positive leaders in an attempt to identify occurrences of CC. However, there was no observed change in positive leader growth rate during CC of negative CG flashes. In this study, we use the Langmuir Electric Field Array, Lightning Mapping Array, and Flash‐Continuous Broadband Digital Interferometer data to extend the previous study to the growth of the negative leader during positive CG flashes. We have found that in contrast with previous results, negative leader growth during positive CG flashes does show increases in growth rates coincident with CC. Finally, we find that the growth rate magnitudes for positive and negative leaders are typically ∼2–4 km/10 ms and ∼25–40 km/10 ms, respectively. These contrasting results highlight the differences between positive and negative leaders and provide strong evidence as to why −CC and +CC behave differently. Negative leaders inject higher amounts of current and allow the channel to remain conductive throughout the duration of CC. Whereas for positive leaders, the channel becomes nonconductive relatively quickly. It is therefore disconnected from the channel to the ground, and, due to the positive leader's continued growth, an electric potential is built up until a K event is produced that re‐ionizes the channel.