An in-vitro cadaver-based measurement using microcomputed tomography. To evaluate the safety of removal of expandable pedicle screws (EPSs) in human vertebral bodies after a long (6 mo) insertion time. Transpedicular fixation is commonly used for posterior fixation of the spine. Osteoporotic patients are in high risk of internal fixation failure. EPS is an available device for increasing transpedical fixation in the osteoporotic spine. However, it is unclear that how much the diameter of the expanding screw tip increases in the human vertebral body, and no reports have assessed the potential for fracture of the pedicle when the EPS is removed. Therefore, the safety of removal of EPS needs to be evaluated. In this study, 6.50 mm EPSs were inserted into cadaveric lumbar vertebrae. The maximum diameters of expansion, the maximum diameters of the EPS trajectories, and the diameters of the EPS trajectories in the pedicles were measured using microcomputed tomography imaging and 3-dimensional reconstruction. Regions of interest of the same size adjacent to the EPS in the pedicle and in the vertebral body were reconstructed and analyzed using the same thresholds (1000). Bone volume divided by total volume (BV/TV) in these regions of interest was determined. The maximum diameter of expansion of the EPSs in the vertebral body was 7.63 mm, a 17.38% increase from the original diameter. The maximum diameter of the EPS trajectory and the diameter of the EPS trajectory in the pedicle were 7.56 mm and 7.09 mm, respectively, increases of 16.31% and 9.08%. The differences were statistically significant (P < 0.05). In the pedicle, there was a negative correlation between the diameter of the EPS trajectory and the BV/TV along the EPS trajectory (r = -0.88; P = 0.002). In the vertebral body, a negative correlation occurred between the maximum expansion diameter of the EPS and vertebral BV/TV (r = -0.85; P = 0.004). The EPS could be reliably removed after expansion without fracturing the pedicle. Furthermore, the BV/TV had an important influence on the degree of expansion of EPS and whether or not pedicle fracture occurs.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.