Abstract

Robotic exoskeletons leverage technology that assists people with spinal cord injury (SCI) to walk. The efficacy of home and community exoskeletal use has not been studied in a randomized clinical trial (RCT). To examine whether use of a wheelchair plus an exoskeleton compared with use of only a wheelchair led to clinically meaningful net improvements in patient-reported outcomes for mental and physical health. This RCT of veterans with SCI was conducted at 15 Veterans Affairs medical centers in the US from September 6, 2016, to September 27, 2021. Data analysis was performed from March 10, 2022, to June 20, 2024. Participants were randomized (1:1) to standard of care (SOC) wheelchair use or SOC plus at-will use of a US Food and Drug Administration (FDA)-cleared exoskeletal-assisted walking (EAW) device for 4 months in the home and community. Two primary outcomes were studied: 4.0-point or greater improvement in the mental component summary score on the Veterans RAND 36-Item Health Survey (MCS/VR-36) and 10% improvement in the total T score of the Spinal Cord Injury-Quality of Life (SCI-QOL) physical and medical health domain and reported as the proportion who achieved clinically meaningful changes. The primary outcomes were measured at baseline, post randomization after advanced EAW training sessions, and at 2 months and 4 months (primary end point) in the intervention period. Device usage, reasons for not using, and adverse events were collected. A total of 161 veterans with SCI were randomized to the EAW (n = 78) or SOC (n = 83) group; 151 (94%) were male, the median age was 47 (IQR, 35-56) years, and median time since SCI was 7.3 (IQR, 0.5 to 46.5) years. The difference in proportion of successes between the EAW and SOC groups on the MCS/VR-36 (12 of 78 [15.4%] vs 14 of 83 [16.9%]; relative risk, 0.91; 95% CI, 0.45-1.85) and SCI-QOL physical and medical health domain (10 of 78 [12.8%] vs 11 of 83 [13.3%]; relative risk, 0.97; 95% CI, 0.44-2.15) was not statistically different. Device use was lower than expected (mean [SD] distance, 1.53 [0.02] miles per month), primarily due to the FDA-mandated companion being unavailable 43.9% of the time (177 of 403 instances). Two EAW-related foot fractures and 9 unrelated fractures (mostly during wheelchair transfers) were reported. In this RCT of veterans with SCI, the lack of improved outcomes with EAW device use may have been related to the relatively low device usage. Solutions for companion requirements and user-friendly technological adaptations should be considered for improved personal use of these devices. ClinicalTrials.gov Identifier: NCT02658656.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.