Abstract

A cogeneration system based on a methane-fed solid oxide fuel cell (SOFC) integrated with a Stirling engine is analyzed from the viewpoints of energy and exergy. The effects on the system performance are investigated of varying four key system parameters: current density, SOFC inlet temperature, compression ratio and regenerator effectiveness. The energy efficiency of the combined system is found to be 76.32% which is about 24.61% more than that of a stand-alone SOFC plant under the same conditions. Considering exergy efficiency as the only objective function, it is found that, as the SOFC inlet temperature increases, the exergy efficiency of the cogeneration system rises to an optimal value of 56.44% and then decreases. The second law analysis also shows that the air heat exchanger has the greatest exergy destruction rate of all system components. The cooling water of the engine also can supply the heating needs for a small home.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.