Abstract

In this paper, exergy analysis successfully assesses the true thermodynamic efficiency of chemical processes. It also indicates the plant irreversibility distribution among plant components, revealing those which contribute most to plant inefficiency. A structural analysis is also performed to determine the effects of some operating parameters on the local irreversibility rates with respect to the overall plant irreversibility rate. This study deals with the application of exergy analysis to raw juice production and the steam-power units of the sugar production plant from sugar beet. The structural bond coefficients of the some operating system parameters are calculated. It is concluded that if the optimal values determined for the operating system parameters in this work were chosen, the total exergy loss of the plant would decrease 4.21%.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.