AbstractThe primary objective of the present paper is to assess the performance of a naphtha‐based combined cycle power plant using the first and second laws of thermodynamics. Heat loss and energy efficiency of each component are calculated by using energy equations. Cogeneration efficiency and efficiency standard have been applied for calculating energy efficiencies. The cogeneration efficiency and efficiency standards are found as 57.87% and 41%, with heat recovery steam generators and auxiliary boilers as the most inefficient units. Further exergy efficiency is found as 30%, with combustion chambers and auxiliary boilers as the most inefficient units. At the end of the analysis, an elaborate appraisal has been made to critically judge the plant as a combined cycle unit. Finally, a few suggestions have been made for further improvement of the plant.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.