Abstract

An exergy analysis has been used for a combination of steam-injected gas turbine cogeneration system and forward-feed triple-effect evaporation process, with and without vapour recompression. The fuel utilization efficiency, power—heat ratio and second-law efficiency are examined for evaluation of the thermal system performance. It is shown that the interaction between the combustion irreversibility and the exhaust exergy losses is dominant in governing the system efficiency with various steam injection ratios and feedstock mass flowrates. The compressor and gas turbine losses are shown to have a relatively small influence.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.