Abstract

AbstractThis work presents a thermodynamic analysis of a triple-level pressure combined power plant with supplementary firing. The supplementary firing is a technological development for improving and increasing the output power of a combined-cycle (CC) power plant. In Mexico, there is a plant operating with this configuration, which generates a net power of 1,170 MW, with a power ratio of the gas turbine (GT) to the steam turbine (ST) of 1.35∶1. This plant is composed of four combined-cycle units with supplementary firing, each providing an output power of 292.5 MW. The energetic and exergetic analyses of the combined cycle with and without supplementary firing are pursued, taking into account the combustion process of natural gas and humid air. These analyses are also carried out for the heat recovery steam generator, considering the waste gases of the gas turbine and of the supplementary firing as the energy sources. The obtained results are fuel, steam, and humid air flows; excess of air; gas and stea...

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.