Abstract

The exchange bias anisotropy field in CoFe/IrMn ferromagnetic/antiferromagnetic bilayers has been investigated by two different experimental probes. One was the traditional hysteresis loop shift technique and the other was a recently developed technique which monitors small reversible rotations of the magnetization with the anisotropic magnetoresistance (AMR). All the samples show approximately twice the exchange bias anisotropy field measured with the AMR technique compared to that measured with the traditional hysteresis loop method. Based on similar experiments in other materials, there is a portion of the exchange bias uniaxial anisotropy which rotates in a hysteresis loop measurement. It is surmised it is this energy which the hysteresis loop technique neglects and that the AMR technique is a better measure of the exchange bias anisotropy energy.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.