Abstract
Interaction of electrocutaneous stimulation with an impaired human motor control system may result in unstable reflex loops causing excessive spastic reactions. These contractions are usually excluded from analysis since the presence of spasm is one of the criteria commonly applied for discarding a contraction. They may, however, provide interesting information on the nature of spasticity. The dorsiflexor muscles of four SCI subjects were activated by means of surface electrical stimulation and the isometric ankle moment was measured. Short bursts of constant stimulation frequency at seven different frequencies (8, 12, 16, 20, 25, 33, 50 Hz) triggered spastic reactions in all subjects. The onset times of spastic activity during an electrically elicited contraction shortened with increased stimulation frequency. A stimulation burst may also have a spasticity reduction effect on a subsequent burst, indicating potential short term therapeutic effects of stimulation on spasticity in isometric conditions.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.