Abstract

Excess molar enthalpies at 298.15 K have been measured for (propan-1-ol + butan-2-one), (propan-1-ol + butan-2-one + benzene), and (propan-2-ol + butan-2-one + benzene) using an isothermal dilution calorimeter. Polynomial equations have been fitted to the experimental results, which are compared with the predictions of an association model with only binary parameters.