Abstract

With the aim to compare the diagnostic efficacy as regards acute myocardial infarction of two rapid dry-strip tests, one with both creatine kinase MB (CK-MB) and myoglobin (C + M) and the other with troponin T, and to test the reliability of bedside diagnosis by the coronary care unit (CCU) nurse, 151 patients with acute chest pain admitted to the CCU were investigated. There was no difference in diagnostic performance between rapid tests and quantitative determinations. With <6-hour duration of symptoms, the sensitivity was better for C + M than for troponin T (72% vs 33%, p < 0.05). With symptoms lasting >12 hours on arrival, troponin T performed better, with 100% sensitivity and a negative predictive value of 100% in the 6-hour retest. For exclusion of damage, the two tests have similar and reliable diagnostic capacities 12 hours after the onset of symptoms. The bedside diagnosis or exclusion of acute myocardial infarction was carried out rapidly (within 20 minutes) and reliably by the CCU nurses. (Am Heart J 1998;135:677-83.)

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.