Abstract

Simultaneous measurements of gas- and aerosol-phase hydrogen peroxide (H2O2) have been made at two sites in Los Angeles, one near the Pacific coast at the University of California at Los Angeles (UCLA), and the other in downtown Los Angeles with close proximity to a heavily traveled freeway (freeway site). At both the freeway and UCLA sites, gas-phase H2O2 levels were similar, averaging 1.17 +/- 1.0 and 1.05 +/- 0.6 ppb, respectively. The particle-associated H2O2 in both fine (PM2.5) and coarse (>PM2.5) modes was higher at the freeway site, as compared to UCLA, by a factor of 2. However, when aerosol-phase H2O2 is normalized to particle mass loadings, the fine-mode H2O2 levels are very similar at the two sites: 0.42 +/- 0.3 and 0.58 +/- 0.3 ng H2O2/microg particle mass at the freeway and UCLA sites, respectively. The normalized coarse-mode H2O2 levels were significantly higher at the freeway site than at UCLA, 1.05 +/- 0.3 and 0.51 +/- 0.3 ng/microg, respectively. Estimating aerosol liquid water content on the basis of relative humidity and aerosol mass, a calculated equivalent H2O2 in aerosol liquid water averages 70 mM, more than 2 orders of magnitude higher than concentrations predicted by gas-particle partitioning (Henry's law), which averages 0.1 mM. This indicates that the sampled particles are capable of generating H2O2 in aqueous solution. These corresponding aqueous-phase H2O2 concentrations in aerosol liquid water exceed levels that have been observed to produce cellular damage to lung epithelial cells in laboratory experiments by at least 3 orders of magnitude. Although most measurements of H2O2 in particles were made using an extraction solution adjusted to pH 3.5, a set of measurements indicates that H2O2 from fine-mode particles extracted in the physiologically relevant pH range 5-7.5 also generate H2O2 with only slightly lowered efficiency; coarse-mode H2O2 production dropped by 75% at the upper end of this range. Finally, a small set of measurements was performed to investigate the degree to which the recently developed Versatile Aerosol Concentrator Enrichment System (VACES) affects H2O2 levels in concentrated ambient aerosols. The VACES appeared to a have minimal impact on particulate H2O2.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call