Abstract

This paper presents a case history involving a failure of water pipeline due to a deep excavation. The case history was analyzed using both the simplified method and more sophisticated finite element modeling. Also presented are the fundamentals of damage assessment of buried pipelines associated with deep excavation-induced ground movements. A number of ground displacement profiles pertinent to the damage assessment are introduced. The results of the analysis indicated that the excessive ground movement was the major cause for the failure. These results were partly supported by the finite element analysis which takes the soil-pipe interaction effect account. It is demonstrated that although conservative, the simplified approach presented in this paper can be effectively used as a first-order method for excavation-induced pipeline damage.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.