Grouping the thin epithelium and thicker superficial lamina propria layers into a single cover layer has been widely adopted in finite element vocal fold models. Recent silicone vocal fold studies have suggested, however, that inclusion of a distinct epithelial layer leads to more physiologically representative motion. This study systematically explores the ramifications of incorporating an epithelial layer into a cover grouping for finite element vocal fold modeling. A membrane model for the epithelium is introduced to facilitate parametric investigation by reducing the mesh density requirement of the epithelium into a single infinitesimally thin layer. Excluding the epithelium entirely leads to increased energy in higher order modes and larger inferior-superior excursion of the folds. Integrating the epithelium into a cover layer with volume-weighted average stiffness results in similar kinematics to that of a model treating the epithelium as a distinct layer. However, the internal stress/strain and contact pressure during collision are higher, and viscous dissipation is lower, when the epithelium is integrated into the cover. Thus, careful treatment of the epithelium is recommended for finite element studies, particularly when employing the models for estimating measures dependent upon internal stress/strain and/or collision pressure, such as vocal dose.