Abstract

This study describes trends in mean standing functional turnout angles measured on a floor protractor (FP) and the Functional Footprint(®) rotational instrument (RI) during routine clinical screens. Twenty-three professional ballet dancers, 26 collegiate modern students, and 46 ballet academy dancers participated in the study. All dancers demonstrated greater total turnout on the FP compared to the RI (p < 0.001), and the collegiate dancers had significantly smaller total turnout angles compared to both of the other groups (p < 0.001). A significant interaction between measurement method and training group (p = 0.047) on lower extremity asymmetry indicated that only in professionals left turnout angle was greater than right turnout angle on the RI (4.30° ± 6.64°) but not on the FP (0.17° ± 4.57°). It is concluded that turnout can be measured using either the FP or the RI measurement method, with recognition that FP measurements will be an average of 10° greater than those on the RI. Lower extremity asymmetries in turnout angles may be better detected on the RI than the FP.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.