In this paper, the results of examining the number of strands for high efficiency and low heat generation of litz wire used for transformer of LLC resonant converter are described. Converter used for switching power supplies are required to be smaller and more efficient. To reduce the size of the converter, examinations have been made by increasing the frequency of the driving frequency. However, due to the high frequency, heat generation in the winding increase due to an increase in AC resistance in the transformer, which is one of the programs of high frequency. In view of this, we study reduction in heat generation by making the wire diameter of the winding constant and changing the number of strands. As a results, it is possible to improve efficiency of the LLC converter by 0.3 % and suppress heat generation of the transformer at 37 °C.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.