Abstract

If the magnetic field in a magnetic device which is operated at high temperature, for example 100 °C, is analyzed using magnetic characteristics at a room temperature ( RT ), there occur some errors. Although the measurement method using a single sheet tester ( SST ) has advantages that the material characteristics can be measured precisely, the research about the correlation between the temperature and the magnetic characteristics using SST is few. In this paper, firstly, the temperature characteristics of magnetic properties of silicon steel sheet were measured using SST, then, the temperature characteristics of the iron loss of the permanent magnet motor were estimated by using the finite element method ( FEM ). It is shown that the permeability is increased at low flux density, and decreased at high flux density when the temperature is increased. The iron loss is decreased similarly in almost all range of Bm. The change of iron loss is remarkable in the low grade steel ( 50A1300 ). The iron loss of SPM motor at 100 °C is decreased by about 10-20 % compared with that at RT.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.