Abstract

Permalloy is used in a magnetically shielded room to inhibit the penetration of external magnetic field, etc. The flux density in permalloy used in the shielded room is of the order of a few mT or lower. In order to examine the performance of such a shielded room, the dc magnetic properties at low flux density is necessary. In this paper, we developed a measurement method of dc (5 mHz) magnetic properties of permalloy under such a low flux density. It is shown that the dc magnetic properties could be measured more than 4 mT by paying the attention to the degaussing of specimen and applying the correction of drift and offset of measurement system.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.