Abstract

Lakes Nyos and Monoun in Cameroon are known as “killer lakes” because they killed ~1,800 people in the mid-80s after a gas explosion or limnic eruption, a sudden release of carbon dioxide accumulated in deep waters. This event attracted the interest of the international scientific community, not only for the sake of disaster mitigation but also for its volcanological significance. Follow-up studies indicated that the CO2 concentration in deep water increased at an alarming rate at both lakes, and that a future gas explosion was likely to occur. To avoid recurrence of the explosion, artificial degassing of the lakes was set up using pipes based on the gas self-lift principle. This chapter compiles the results of the geochemical monitoring of the two lakes for the last 25 years. Pre- and syn-degassing evolution of CO2 profiles was translated into the temporal changes of CO2 content in the lakes, and thus estimate CO2 recharge and removal rates. Degassing went on smoothly, and more than 90 % of the maximum amount of CO2 was removed from Lake Monoun by 2011, reaching safe levels. Since the lake has lost its gas self-lift capability, degassing will no longer continue. At Lake Nyos, degassing is on-going and 33 % of the maximum amount of CO2 has now been removed. A model of spontaneous gas exsolution is proposed. This idea is based on the temporal variation of CO2 profiles at Lake Monoun between 1986 and 2003. During this period the profiles evolved rather steadily, i.e., the deep CO2-rich layer thickened while its CO2 concentration remained constant. This suggests that the recharge fluid coming from depth had a CO2 concentration similar to that of the bottom water, and that it pushed the deepest water upward, resulting in CO2 saturation at the top of the CO2-rich layer, which led to the 1984 limnic eruption. A similar situation was observed at Lake Nyos just before the degassing operation started in 2001, i.e., the deep, CO2-rich layer thickened while its CO2 concentration remained unchanged at about 350 mmol/kg, which is still far below CO2 saturation. In this lake, pre-degassing deep water had low CO2/3He ratios (~0.5 × 1010), whereas the recharge fluid was characterized by relatively high CO2/3He ratios (~1.7 × 1010). This suggests that the behavior of CO2 and He in the lake was decoupled. The recharge fluid is likely produced by mixing of magmatic fluids, which are characterized by relatively high 3He/4He, 40Ar/36Ar, 20Ne/22Ne and 21Ne/22Ne ratios, with groundwater having air isotopic signatures.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.