Abstract

To present long-term follow-up data on eviscerations carried out with scleral modification and placement of spherical porous polyethylene implants. We conducted a retrospective, interventional study on eviscerations performed with four anterior relaxing incisions and posterior sclerotomies made circumferentially behind the equator at approximately 330° and placement of porous polyethylene spherical implant, performed between March 2000 and August 2007 by a single surgeon. Patient age, sex, causative diagnosis, axial length, implant size, follow-up duration, complications and treatment were recorded. In total, 92 patients were identified. The mean implant size was 19.46 mm. During the follow-up period (mean: 60 months, range: 19-107 months), there were no cases of implant exposure. In some patients, mild discharge, ptosis and conjunctival cysts developed. Primary evisceration with four anterior relaxing incisions and posterior sclerotomies made circumferentially behind the equator at approximately 330°, combined with porous polyethylene orbital implant placement, is a useful technique for treating a variety of end-stage eye diseases.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.