Abstract

An abandoned clandestine laboratory was seized in Slovenia. All confiscated exhibits were analysed in a forensic laboratory, where the following analytical methods were applied: capillary gas chromatography coupled with mass spectrometry (GC–MS) combined also by solid-phase micro extraction (SPME) and pyrolysis (Py) technique, Fourier transform infrared spectrometry (FTIR) and scanning electron microscopy with energy dispersive X-ray detector (SEM–EDX). The most interesting analytical findings can be summarised as follows: at the crime scene some plastic pieces, which contained cocaine dissolved (as solid solution) in polymethyl methacrylate-plexiglass (PMMA), were found. The highest cocaine concentration measured in the plastic sample was about 15% by weight. Two larger lumps of material (12 and 3 kg) were composed mainly of PMMA and CaCO 3 and contained only 0.4 and 0.5% of cocaine, respectively. As for the low cocaine concentration, we assume that those two lumps of material represent discarded waste product—residue after the isolation of cocaine from plastic. Higher quantities of pure solvents (41 l) and solvent mixtures (87 l) were seized. We identified three types of pure solvents (acetone, gasoline and benzine) and two different types of solvent mixtures (benzine/acetone and gasoline/acetone). The total seized volume (87 l) of solvent mixtures holds approximately 395 g of solid residue formed mainly of PMMA and cocaine. Obviously solvent mixtures were used for isolation of cocaine from the plastic. Small quantities of relatively pure cocaine base were identified on different objects. There were two cotton sheets, most probably used for filtration. One sheet had traces of cocaine base (76% purity) on the surface, while cocaine in hydrochloride form (96%) was identified on the other sheet. GC–MS analyses of micro traces isolated from analytical balances showed the presence of cocaine and some common adulterants: phenacetine, lidocaine and procaine. A cocaine sample compressed in the shape of block was also seized. The above analytical findings inferred us to the conclusion that the illicit laboratory was used for the isolation of cocaine from PMMA resin. Further more, analyses confirm that not only isolation but also further manipulation of cocaine, i.e. adulteration/dilution, as well as the formation of cocaine blocks took place in the house. The information obtained through analyses also allowed us to make some hypotheses about possible multistage isolation procedure.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.