Abstract

Probabilistic safety assessment has been widely used to evaluate nuclear power plant safety systems. It couples fault tree (FT) analysis and event tree (ET) analysis. FT analysis is to develop failure scenarios, to quantify the failure probability and to identify critical components. ET analysis is to develop event sequences (ESs) leading to reactor core damage and quantify core damage frequency. Currently, there is no approach in probabilistic safety assessment that can be used to identify minimal combinations of safety system failures leading to reactor core damage. This study proposes an event sequence based fault tree analysis, which integrates FT model with ET model. The ET model is to identify the ESs leading to the reactor core damage. Meanwhile, the FT model is to identify minimal combinations of those ESs found in the ET model. The motivation of this study is on how to identify critical safety systems in nuclear power plants to mitigate disturbances caused by a group of postulated initiating events to avoid core damage. To confirm the feasibility and the applicability of the proposed approach, the performance of the AP1000 passive core cooling system is evaluated. It is found that if in-containment refueling water storage tank, automatic depressurization system - full, accumulator, core make-up tank, and passive residual heat removal work properly, the reactor core will intact. These results confirmed that the proposed approach can be applicable to identify minimal combinations of safety systems to keep the reactor core intact.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call