Abstract

Abstract Many industrial processes generate mineral oil mist. Current control technologies focus only on removing the mist droplets from the air. However, if these droplets evaporate, the vapor can pass through a collector designed to remove droplets alone. The purpose of this study was to determine the extent of evaporation for mineral oil droplets introduced to a mist collection system. Vapor was sampled using activated carbon downstream from the collector as high concentrations (45 to 55 mg/m3) of oil mist were injected upstream. After the system was loaded with mist, additional vapor samples were taken without mist injection to determine the amount of evaporation from mist-loaded collector components. The average vapor concentration measured for all samples taken when oil mist was introduced to the system was 4.02 mg/m3, or 8.8 percent of all oil introduced. Vapor concentrations caused by evaporation from collector components declined from 3 to 5 mg/m3 as clean air initially passed through freshly loa...

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.