Abstract

A 30-mm-long multimode waveguide, 40 mum wide and 40 mum high, is fabricated on a silicon wafer using polymer SU-8 as the core and liquid buffer as the cladding. Antibodies are successfully immobilized on the SU-8 surface designated for binding target antigens dispersed in the buffer solution. Evanescent-wave spectroscopy is performed by exciting the fluorescently labeled antigens, bound to the waveguide surface within its evanescence field, and measuring the emission light intensity. This evanescent-wave biosensor detects specific molecular interaction. The optical output as a function of the antigen concentration can be described by Langmuir equation. Antigen concentration as low as 1.5 mug/mL is detected; concentrations higher than 100 mug/mL lead to sensor saturation.