Abstract

The “in programming barium fluoride (BaF2) detector array” is one of the experiment facilities at China Spallation Neutron Source-White Neutron Sources, which is designed for the measurement of neutron capture cross section with high accuracy. It consists of 92 crystal elements with completely $4\pi $ solid-angle coverage, which needs 92 analog channels and 92 digitization channels for data acquisition. Accordingly, the readout electronics is comprised with four distributed readout PXIe crates, containing 46 field digitization modules (FDMs). Each FDM supports two valid channels for signal digitizing. In this paper, evaluation software is designed for evaluating the performance of BaF2 readout electronics. It focuses on evaluating the performance of data transmission, waveform digitizing, and working status monitoring. Test results show that the evaluation software can correctly acquire and assemble data from the BaF2 readout system and evaluate the analog digital converter (ADC) performance under ADC test mode. FDMs in the readout system can also be monitored and controlled by this software in real time.