This paper presents investigation study on the failed reheater tube by finite element modeling, dimensional measurements and microscopic examinations. The failed tube was situated in horizontal position and facing directly to the incoming hot flue gas from furnace region. Scale thickness of as-received tube samples of the failed tube and its neighbor tubes is measured in order to estimate the average scale growth rates. The estimated scale growth rate is used to generate geometries of the scale for finite element models. Operational and allowable stresses of the tube at the corresponding average tube temperatures and service hours are presented. Results obtained from finite element analysis are shown to be in good conformity with the findings from the microscopic examination.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.