Abstract
Physical and in vivo (burned rat model) evaluations as wound coverings were performed for 1) a freeze-dried collagen/poly (epsilon-caprolactone) (PCL) film laminate, 2) a freeze-dried PCL "foam"/PCL film laminate, and 3) a heat-dried collagen/PCL film laminate. Porcine skin and cadaver skin were also evaluated in vivo for the purpose of comparison. Water-vapor transmission rates and Young's moduli were measured. The degree of adherence of the coverings to the wound were measured. Grafts which became significantly adherent (greater than 150 dyne/cm2) to the wound within 1 day were most successful in promoting the formation of a viable tissue bed which appeared ready to accept further grafting. The force required to remove the PCL foam laminate from a full-thickness excision wound was found to increase from 170 dyne/cm2 on the first day postgraft to 1500 dyne/cm2 by the tenth day. The force required to remove freeze-dried collagen laminate remained constant at 200 dyne/cm2 over the 10 day test period. For the heat-dried collagen laminate, a force of only 50 dyne/cm2 was required on day 1, increasing to 200 dyne/cm2 on day 6. Insensible water-loss rates of animals grafted with the laminates were found to be similar to those from animals with human cadaver skin grafts and less than that from animals with porcine skin grafts. When moistened, the laminates prepared using the freeze-dried materials were flexible and somewhat transparent permitting observation of the wound.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.