Abstract

A novel scheme is proposed for online condition monitoring of bond wires present in insulated gate bipolar transistor (IGBT) package. The proposed method detects bond wire degradation using on-state collector emitter voltage at the inflection point. Previously reported condition monitoring methods based on on-state collector-emitter voltage as a precursor of aging require an accurate knowledge of junction temperature which is difficult to measure online during an inverter operation. The key advantage of the proposed scheme is that it monitors the bond wire degradation irrespective of the junction temperature. Therefore, this technique is not affected by increase in junction temperature due to die attach degradation or change in ambient temperature. The proposed scheme is verified experimentally under realistic operating conditions.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.