Abstract

Purpose Underdosage in the human larynx may be the true factor behind the decrease in local control rates. Patients and methods To evaluate underdosage with Monte Carlo a CT-based geometrical model of the patient's neck (mathematical neck) was created. Dose was calculated for a pair of 6 Me V parallel-opposed photon beams modulated with 15 degree steel wedges. Results At least 5% of volume of 3.5 cm 3 hypothetical tumor near the air wall of the larynx receives less than 86% of the maximum tumor dose. The same volume received less than 91% of the maximum tumor dose when the mathematical neck had no air cavities. Conclusions We conclude the significant underdosage at the air-tissue interface in the larynx occurs in traditional radiotherapy treatments, especially in the glottic part of the larynx.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.