Abstract
Buckling of slender load-bearing beam-columns is a crucial failure scenario in light-weight structures as it may result in the collapse of the entire structure. If axial load and load capacity are unknown, stability becomes uncertain. To compensate this uncertainty, the authors successfully developed and evaluated an approach for active buckling control for a slender beam-column, clamped at the base and pinned at the upper end. Active lateral forces are applied with two piezoelectric stack actuators in opposing directions near the beam-column' clamped base to prevent buckling. A Linear Quadratic Regulator is designed and implemented on the experimental demonstrator and statistical tests are conducted to prove effectivity of the active approach. The load capacity of the beam-column could be increased by 40% and scatter of buckling occurrences for increasing axial loads is reduced. Weibull analysis is used to evaluate the increase of the load capacity and its related uncertainty compensation.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.