Abstract
BackgroundEnteral nutrition should be implemented as early as possible in patients with moderate or severe acute pancreatitis. This study was designed to evaluate the feasibility and Deffectiveness of ultrasound-guided Freka-Trelumina tube placement for enteral nutrition in acute pancreatitis.MethodsPatients with severe acute pancreatitis admitted to Shengjing Hospital of China Medical University who needed Freka-Trelumina tube placement for enteral nutrition and gastrointestinal decompression were included in the current study. The relevant evaluation indicators of tube placement included the success rate of tube placement, tube placement time, tube shift rate, and blocking rate. In addition, the evaluation indicators of ultrasound-guided tube placement (from 1 January 2018 to 31 July 2019) were compared with those of previous endoscope-guided placement (from 1 January 2015 to 31 December 2017) by analysing the data from the electronic medical record system.ResultsThe success rate of ultrasound-guided tube placement was 90.7% (49/54). All 49 patients tolerated the Freka-Trelumina feeding tube. The average ultrasound-guided tube placement time for the 49 patients was 18.4 ± 12.8 min (range, 5–36 min). The Freka-Trelumina feeding tube had a shift rate of 10.2% (5/49). The blocking rate of the Freka-Trelumina feeding tube was 12.2% (6/49). The success rate of tube placement, tube shift rate and blocking rate for endoscope-guided tube placement were 100% (62/62), 11.3% (7/62), and 12.9% (8/62), respectively. The average endoscope-guided tube placement time for the 62 patients was 16.5 ± 5.7 min (range, 12–31 min). The comparison between the ultrasound-guided group and the endoscope-guided group showed that the success rate of tube placement, tube placement time, tube shift rate and blocking rate were similar.ConclusionThe ultrasound-guided method can be done non-invasively at the bedside, which is safe and convenient, and the Freka-Trelumina feeding tube can be placed in time to achieve the goal of early enteral nutrition and gastrointestinal decompression.
Highlights
Enteral nutrition should be implemented as early as possible in patients with moderate or severe acute pancreatitis
Ultrasound-guided Freka-Trelumina enteral nutrition tube placement A sterile towel was spread on the operating room table, and warm water was poured into the dressing bowl
This study showed that the success rate of ultrasoundguided Freka-Trelumina feeding tube placement was as high as 90.7% (49/54)
Summary
Enteral nutrition should be implemented as early as possible in patients with moderate or severe acute pancreatitis. This study was designed to evaluate the feasibility and Deffectiveness of ultrasound-guided Freka-Trelumina tube placement for enteral nutrition in acute pancreatitis. Evidence-based medical evidence indicates that early enteral nutrition can preserve intestinal mucosal barrier function in patients with severe acute pancreatitis and. There are currently three placement methods for FrekaTrelumina enteral nutrition tubes (blind, radiographyguided, and endoscope-guided placement) [10,11,12,13,14,15]. Liu et al BMC Gastroenterology (2020) 20:21 with patient transportation and the discomfort and damage associated with the gastroscope method, and it can be conveniently performed non-invasively at the bedside. This study was designed to evaluate the feasibility and effectiveness of ultrasound-guided Freka-Trelumina tube placement for enteral nutrition in acute pancreatitis
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.