Abstract

Concrete walls used in a fusion reactor or a tritium handling facility have the important role of separating the atmosphere in a facility from environmental air, since substantial tritium leakage is possible from a tritium system to the atmosphere of a tritium handling facility. Therefore, it is necessary to understand the transfer behavior of tritium through concrete. The experiments of this study were performed to observe the change of the tritium distribution with time in columns made of cement paste, mortar or concrete. It was found that exposure of the surface of concrete materials to HTO vapor for two months produced tritium permeation to the depth of 30 mm. Estimation of tritium penetration behavior was also performed in this study by applying adsorption, desorption and isotope exchange reactions and the estimated tritium profile was in good agreement with observed values.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.