Abstract
IntroductionThe use of orthopedic implants is a cause for concern for the release of its integrating metals and the systemic complications that may occur. Instrumented spine arthrodesis is the recommended treatment for many spine diseases. Different segmental fixation devices, commonly made of titanium and its alloys, are used in these surgeries. The use of this metal for spinal fusion has introduced the possibility of generating microscopic metal particles that are present in the tissues of the surrounding implants (peri-implant environment). In fact, metal debris has been found in the paraspinal soft tissues of patients with posterior lumbar instrumentation and showed to be particularly high in patients undergoing revision procedures of pseudoarthrosis. In addition, part of the metals might also dissolve (either from the released particles or directly from the implant surface) and circulate in the body fluids, accumulating (eventually) in remote organs.Material and methodsA prospective study was designed with patients who were to be operated by the pathology of the lumbar spine to perform a vertebral arthrodesis composed of a titanium alloy (n=32). Two subgroups were differentiated according to the type of surgery performed: a) Posterolateral arthrodesis (N=5); b) Circumferential arthrodesis intervertebral implant of polyester-ether ketone (PEEK) (N=8) or titanium (N=19). The blood sample was taken before surgery and one year later. The samples were analyzed by mass spectrophotometry with a double focus inductive coupling plasma source (DF-ICP-MS).ResultsBlood titanium levels prior to surgery were similar to those in other publications (0.7449 micrograms per liter-1 (µgL-1), Standard Deviation (SD)=0.562). The average titanium concentration levels found after surgery was 2.5406 µgL-1 (SD=3,69), near 3.5-fold increase. After surgery, there was a significant mean increase in serum titanium levels of 1.7957 µgL-1 (SD=3.5765, Range=-0.57 µgL-1; 14.60 µgL-1). There is a statistically significant increment (p=0.00049) of the titanium concentration in the serum of the patients after surgery. If we analyze the patients in three groups according to the type of implants used (posterolateral, circumferential with PEEK, and circumferential with titanium), there are no differences between those who did not have an intersomatic device implanted and those in which PEEK implants were implanted, but with those in which it was titanium it was p=0.006 and p=0.018, respectively.ConclusionsPatients undergoing vertebral instrumentation experience a significant increase in serum titanium levels compared to before surgery levels. The use of an intersomatic device did not show differences in titanium release with not using it when it was PEEK. There are significant differences between patients without intersomatic implants or those who had a PEEK implant with those in whom it was titanium, with a significant increase in blood titanium levels.
Highlights
The use of orthopedic implants is a cause for concern for the release of its integrating metals and the systemic complications that may occur
Patients undergoing vertebral instrumentation experience a significant increase in serum titanium levels compared to before surgery levels
Instrumented spinal arthrodesis is the recommended treatment for progressive spine deformity and degenerative disc disease. For these kinds of surgeries, different segmental fixation devices, including hooks, screws, wires, etc., commonly made of titanium and its alloys, are used [1]. The use of this metal for spinal fusion has introduced the possibility of generating microscopic metal particles, which are present in the tissues of the surrounding implants [2]
Summary
The use of orthopedic implants is a cause for concern for the release of its integrating metals and the systemic complications that may occur. Commonly made of titanium and its alloys, are used in these surgeries. The use of this metal for spinal fusion has introduced the possibility of generating microscopic metal particles that are present in the tissues of the surrounding implants (peri-implant environment). Metal debris has been found in the paraspinal soft tissues of patients with posterior lumbar instrumentation and showed to be high in patients undergoing revision procedures of pseudoarthrosis. Part of the metals might dissolve (either from the released particles or directly from the implant surface) and circulate in the body fluids, accumulating (eventually) in remote organs
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.