Abstract

BackgroundWhole exome sequencing (WES) has been widely accepted as a robust and cost-effective approach for clinical genetic testing of small sequence variants. Detection of copy number variants (CNV) within WES data have become possible through the development of various algorithms and software programs that utilize read-depth as the main information. The aim of this study was to evaluate three commonly used, WES read-depth based CNV detection programs using high-resolution chromosomal microarray analysis (CMA) as a standard.MethodsPaired CMA and WES data were acquired for 45 samples. A total of 219 CNVs (size ranged from 2.3 kb – 35 mb) identified on three CMA platforms (Affymetrix, Agilent and Illumina) were used as standards. CNVs were called from WES data using XHMM, CoNIFER, and CNVnator with modified settings.ResultsAll three software packages detected an elevated proportion of small variants (< 20 kb) compared to CMA. XHMM and CoNIFER had poor detection sensitivity (22.2 and 14.6%), which correlated with the number of capturing probes involved. CNVnator detected most variants and had better sensitivity (87.7%); however, suffered from an overwhelming detection of small CNVs below 20 kb, which required further confirmation. Size estimation of variants was exaggerated by CNVnator and understated by XHMM and CoNIFER.ConclusionLow concordances of CNV, detected by three different read-depth based programs, indicate the immature status of WES-based CNV detection. Low sensitivity and uncertain specificity of WES-based CNV detection in comparison with CMA based CNV detection suggests that CMA will continue to play an important role in detecting clinical grade CNV in the NGS era, which is largely based on WES.

Highlights

  • Whole exome sequencing (WES) has been widely accepted as a robust and cost-effective approach for clinical genetic testing of small sequence variants

  • Size distribution of copy number variants (CNV) detected via chromosomal microarray analysis (CMA) and WES A total of 219 CNVs were detected via CMA from all samples

  • Forty-eight CNVs were located in regions that had no exome capture probes; they were removed from being used as true CNVs when comparing data between CMA and next-generation sequencing (NGS)

Read more

Summary

Introduction

Whole exome sequencing (WES) has been widely accepted as a robust and cost-effective approach for clinical genetic testing of small sequence variants. The aim of this study was to evaluate three commonly used, WES read-depth based CNV detection programs using high-resolution chromosomal microarray analysis (CMA) as a standard. Chromosomal microarray analysis (CMA) has demonstrated its technical validity and has remained the method of choice for the detection of genome-wide copy number variants (CNVs) in clinical settings. It has demonstrated its clinical validity for both pre- and. Whole-exome sequencing (WES) has been accepted as the most comprehensive test currently implemented in the clinical setting for small sequence variants [9, 10]. Its technical validity has yet to be thoroughly evaluated

Objectives
Methods
Results
Discussion
Conclusion
Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call