Abstract

The diagnostic capacity of three malaria rapid diagnostic tests (RDTs), NOW-Malaria-ICT, OptiMAL-IT, and Paracheck-Pf, was evaluated against expert microscopy in Colombia. We tested 896 patients, of whom microscopy confirmed 139 P. falciparum, 279 P. vivax, and 13 mixed P.f/P.v infections and 465 negatives. Paracheck-Pf and NOW-malaria-ICT were more accurate in detecting P. falciparum (sensitivities 90.8% and 90.1%, respectively) in comparison with Optimal-IT (83.6%). NOW showed an acceptable Pf detection rate at low densities (< 500/microL), but resulted in a higher proportion of false positives. For P. vivax diagnosis, Optimal-IT had a higher sensitivity than NOW (91.0% and 81.4%, respectively). The choice between the two Pf/Pv detecting RDTs balances P. falciparum and P. vivax detection rates. Considering some degree of P. falciparum overtreatment and failure to detect all P. vivax cases as more acceptable than missing some cases of P. falciparum, we recommend careful implementation of NOW-malaria-ICT in areas where microscopy is lacking. The price is however still a constraint.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.