Abstract
We evaluated performance of three commercial Japanese encephalitis virus (JEV) IgM antibody capture enzyme-linked immunosorbent assay (MAC ELISA) kits with a panel of serological specimens collected during a surveillance project of acute encephalitis syndrome in India and acute meningitis and encephalitis syndrome in Bangladesh. The serum and cerebral spinal fluid specimens had been referred to the Centers for Disease Control and Prevention (CDC) for confirmatory testing. The CDC results and specimen classifications were considered the reference standard. All three commercial kits had high specificity (95-99.5%), but low sensitivities, ranging from 17-57%, with both serum and cerebrospinal fluid samples. Specific factors contributing to low sensitivity compared with the CDC ELISA could not be determined through further analysis of the limits and dilution end points of IgM detection.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: The American Society of Tropical Medicine and Hygiene
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.