Abstract

This study aimed to create a thick hydroxyapatite (HA) film on the surface of a human tooth via a powder jet deposition (PJD) device for dental handpieces, and to examine the microstructural and mechanical properties of the HA film. In particular, the effects of thermal stress on this film were evaluated. The HA film was created by blasting 3.18-μm HA particles, calcinated at 1,200°C, onto the enamel substrate at room temperature and atmospheric pressure. An HA film with an area of 3 mm × 3 mm was prepared and polished. The following HA film parameters were evaluated from the three-dimensional surface profile: surface roughness, Vickers hardness, and bonding strength before and after artificial aging induced by 500 cycles of thermal cycling (5-55°C). The HA particles in the deposited film were densely packed, and the surface of the HA film was unchanged after thermal cycling. There were also no significant differences in the hardness and the bonding strength of the HA film before and after thermal cycling. The HA film created in this study demonstrated excellent microstructural and mechanical properties, even after the application of thermal stress.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call