Abstract
This research studied a scaling analysis for the selection of proper heat generation at tube for 1/4-scale storage vaults. First of all, the temperature field and velocity distribution of an original scale storage vault were analyzed and then numerical analysis of a 1/4-scale storage vault was performed to compare each model. The proper heat generation for a 1/4-scale storage vault, at which the temperature and velocity field of a 1/4-scale storage vault showed the best agreement with that of the original storage vault, was evaluated with proposed dimensionless parameters. The behavior of temperature and velocity of fluid in the 1/4-scale case were most similar to those of the original scale, using a heat flux 1.3 times higher than that seen in the original scale, which was approximately 190 W.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: Journal of Nuclear Fuel Cycle and Waste Technology
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.