Abstract
A visible light-cured reline resin presently marketed is used directly in the mouth to record the tissue. The viscosity of the material will therefore have an effect on the success of the reline. This article compares the viscoelastic properties of the currently marketed visible light-cured material with a medium-body rubber base material. A cone and plate viscometer was used to help derive the apparent viscosity and flow index of the materials. Readings were recorded with varying shear rates at 25 degrees C and 37 degrees C. The visible light-cured resin was found to have a higher apparent viscosity and flow index than the medium-body rubber base at low shear rates. Temperature had an indirect relationship with the viscosity.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.