Abstract
The time-dependent voltage across the pick-up electrodes of a four point probe has been determined analytically for a transient current pulse injected into a thick conductive plate modeled as a half-space. This is a step towards analyzing more complex transient four point probe signals from measurements on inhomogeneous conductors. Potential applications include the evaluation of depth-dependent conductivity profiles in metals and semiconductors. The analysis of homogeneous conductors shows how the signals are characterized by a time constant of the drive current and additional time constants dependent on the electromagnetic material properties and electrode spacings.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.