Abstract

To test the ThinPrep Processor for fine needle aspiration. One hundred unfixed, surgically removed specimens were aspirated. One pass was directly smeared, fixed and stained with the Papanicolaou technique. The other pass was rinsed in a proprietary fixative, and a single ThinPrep slide was made. Smears were diagnosed without knowledge of the histologic diagnosis. Cellularity and architectural integrity of cell groups were superior on the conventional slides. Preservation and detail of both epithelial and stromal cells were superior with the ThinPrep Processor. Preservation of background material, such as mucus and colloid, was slightly superior on the ThinPrep slides. Diagnostic sensitivity and specificity for malignancy and unsatisfactory rates were all slightly better on the ThinPrep slides. The ThinPrep Processor offers an alternative to direct smears in situations in which expertise in slide preparation is not available.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.