Abstract

After decades of operation in nuclear power plants, Once-Through Steam Generators (OTSGs) were recently proposed for nuclear fusion applications. In particular, they are supposed to be installed in the primary cooling systems of the European Union Demonstration fusion power plant (EU-DEMO). One of the key reactor components is the Breeding blanket (BB). Among the BB concepts that are currently under study, Water-Cooled Lithium-Lead (WCLL) option was considered for this work. The WCLL blanket is divided in two main subsystems, the breeder zone (BZ) and the first wall (FW), each one provided with an independent cooling circuit, named Primary Heat Transfer System (PHTS). Thermal power removed from BB by BZ and FW PHTS is driven to the Power Conversion System (PCS) to be converted into electricity. The thermal coupling is ensured by two OTSGs per system. At the Department of Astronautical, Electrical and Energy Engineering (DIAEE) of Sapienza University of Rome, a simulation activity was carried out to understand the component thermal-hydraulic behavior during DEMO normal operations. For calculation purposes, a full model of the steam generator was prepared by using a modified version of RELAP5/MOD3.3 system code. The computational activity performed allows to preliminary characterize the OTSG thermal-hydraulic performances during both pulse and dwell phases.